Article

Tissue optics.

Biomedical Optics Group at the Medical Free Electron Laser Program, Hansen Experimental Physics Laboratory (HEPL), Stanford University, Stanford, CA 94034, USA.
Science (Impact Factor: 31.48). 07/1997; 276(5321):2002-3.
Source: PubMed
0 Followers
 · 
55 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Control of gene expression often involves an interwoven set of regulatory processes. As information regarding regulatory pathways may be lost in ex vivo analyses, we used bioluminescence to monitor gene expression in living mammals. Viral promoters fused to firefly luciferase as transgenes in mice allowed external monitoring of gene expression both superficially and in deep tissues. In vivo bioluminescence was detectable using either intensified or cooled charge-coupled device cameras, and could be detected following both topical and systemic delivery of substrate. In vivo control of the promoter from the human immunodeficiency virus was demonstrated. As a model for DNA-based therapies and vaccines, in vivo transfection of a luciferase expression vector (SV-40 promoter and enhancer controlling expression) was detected. We conclude that gene regulation, DNA delivery and expression can now be noninvasively monitored in living mammals using a luciferase reporter. Thus, real-time, noninvasive study of gene expression in living animal models for human development and disease is possible.
    Photochemistry and Photobiology 11/1997; 66(4):523-31. DOI:10.1111/j.1751-1097.1997.tb03184.x · 2.68 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Conventional brain-imaging modalities may be limited by high cost, difficulty of bedside use, noncontinuous operation, invasiveness or an inability to obtain measurements of tissue function, such as oxygenation during stroke. Our goal was to develop a bedside clinical device able to generate continuous, noninvasive, tomographic images of the brain using low-power nonionizing optical radiation. We modified an existing stage-based time-of-flight optical tomography system to allow imaging of patients under clinical conditions. First, a stationary head-band consisting of thin, flexible optical fibers was constructed. The headband was then calibrated and tested, including an assessment of fiber lengths, the existing system software was modified to collect headband data and to perform simultaneous collection of data and image reconstruction, and the existing hardware was modified to scan optically using this headband. The headband was tested on resin models and allowed for the generation of tomographic images in vitro; the headband was tested on critically ill infants and allowed for optical tomographic images of the neonatal brain to be obtained in vivo.
    Photochemistry and Photobiology 10/1998; 68(3):361-9. DOI:10.1111/j.1751-1097.1998.tb09693.x · 2.68 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Medical optical imaging (MOI) uses light emitted into opaque tissues to determine the interior structure. Previous reports detailed a portable time-of-flight and absorbance system emitting pulses of near infrared light into tissues and measuring the emerging light. Using this system, optical images of phantoms, whole rats, and pathologic neonatal brain specimens have been tomographically reconstructed. We have now modified the existing instrumentation into a clinically relevant headband-based system to be used for optical imaging of structure in the neonatal brain at the bedside. Eight medical optical imaging studies in the neonatal intensive care unit were performed in a blinded clinical comparison of optical images with ultrasound, computed tomography, and magnetic resonance imaging. Optical images were interpreted as correct in six of eight cases, with one error attributed to the age of the clot, and one small clot not seen. In addition, one disagreement with ultrasound, not reported as an error, was found to be the result of a mislabeled ultrasound report rather than because of an inaccurate optical scan. Optical scan correlated well with computed tomography and magnetic resonance imaging findings in one patient. We conclude that light-based imaging using a portable time-of-flight system is feasible and represents an important new noninvasive diagnostic technique, with potential for continuous monitoring of critically ill neonates at risk for intraventricular hemorrhage or stroke. Further studies are now underway to further investigate the functional imaging capabilities of this new diagnostic tool.
    Pediatric Research 02/1999; 45(1):54-9. DOI:10.1203/00006450-199901000-00009 · 2.84 Impact Factor
Show more

Preview

Download
1 Download
Available from