Normal lower limblood velocityenous Doppler flow phasicity: Is it cardiac or respiratory?

Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City 52242, USA.
American Journal of Roentgenology (Impact Factor: 2.74). 01/1998; 169(6):1721-5. DOI: 10.2214/ajr.169.6.9393197
Source: PubMed

ABSTRACT The purposes of this study were to determine the origin and nature of normal lower limb venous Doppler flow phasicity and to assess normal and respiratory variations.
The common femoral veins of 12 healthy volunteers (three men and nine women; age range, 21-50 years; mean, 29 years) were evaluated by detailed spectral Doppler examinations with simultaneous ECG and respirometric tracings. The examinations were performed using a 5- or 7-MHz linear-array transducer with breath held in mid respiration, at the end of deep expiration, at the end of deep inspiration, during Valsalva's maneuver, and during quiet and deep breathing. The tracing obtained during breath-hold in mid respiration was considered the baseline. Tracings obtained during the other respiratory phases were analyzed for changes from the baseline. Doppler tracings were analyzed for phasicity, waveform frequency, components, velocities, velocity ratios, and presence of retrograde flow, all in correlation with simultaneous ECG and respirometric tracings. Tracings were analyzed independently by two observers to assess interobserver variability.
With breath-hold in mid respiration, the common femoral vein Doppler tracings consisted of multiphasic waveforms that had a frequency similar to that of the heart rate. Each waveform consisted of systolic, v, diastolic, and a waves. The systolic wave occurred 0.4 sec later than the QRS complex of the ECG and was always antegrade. The v wave was always retrograde without flow reversal. The diastolic wave was always antegrade. The a wave was always retrograde but showed flow reversal in nine of 12 subjects. The systolic:diastolic velocity ratio ranged from 0.9 to 1.5 (mean, 1.1). The minimum:maximum velocity ratio ranged from -0.4 to 0.2 (mean, -0.15). With breath-hold at the end of expiration, the waveforms became slightly damped, becoming biphasic in five subjects and remaining multiphasic in seven. With breath-hold at the end of inspiration, the waveforms became nonphasic or biphasic in nine and decreased in velocity in 12. With Valsalva's maneuver, flow stopped. With normal respiration, cardiac waveforms were modulated by higher amplitude and less frequent biphasic respiratory waves. The plasticity was equal in two, dominantly cardiac in six, and dominantly respiratory in four. Flow velocity increased with expiration and decreased with inspiration. With deep breathing, the respiratory waves further increased, while the cardiac ones decreased in amplitude. The latter continued to modulate the respiratory phasicity in 10 subjects.
During quiet respiration, lower limb venous Doppler tracings consisted of both cardiac and respiratory waveforms. Although respiratory waveforms disappeared when patients held their breath, Doppler tracings continued to be multiphasic and cardiac. Therefore, cardiac phasicity in lower limb venous Doppler tracings does not necessarily indicate cardiac disease. Other respiratory phases can modulate this basic cardiac pattern. Decrease in or loss of phasicity in these waveforms does not always mean proximal obstruction, because it can be caused by respiratory factors. Finally, the presence of minimal cyclic retrograde flow that is 5 cm/sec or less does not necessarily indicate cardiac disease.

0 Followers
 · 
1,124 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The current commercially available sequential intermittent pneumatic compression device used for the prevention of deep venous thrombosis has a constant cycle of 11 seconds' compression and 60 seconds' deflation. This deflation period ensures that the veins are filled before the subsequent cycle begins. It has been suggested that in some positions (eg, semirecumbent or sitting) and with different patients (eg, those with venous reflux), refilling of the veins may occur much earlier than 60 seconds, and thus a more frequent cycle may be more effective in expelling blood proximally. The aim of the study was to test the effectiveness of a new sequential compression system (the SCD Response Compression System), which has the ability to detect the change in the venous volume and to respond by initiating the subsequent cycle when the veins are substantially full. In an open controlled trial at an academic vascular laboratory, the SCD Response Compression System was tested against the existing SCD Sequel Compression System in 12 healthy volunteers who were in supine, semirecumbent, and sitting positions. The refilling time sensed by the device was compared with that determined from recordings of femoral vein flow velocity by the use of duplex ultrasound scan. The total volume of blood expelled per hour during compression was compared with that produced by the existing SCD system in the same volunteers and positions. The refilling time determined automatically by the SCD Response Compression System varied from 24 to 60 seconds in the subjects tested, demonstrating individual patient variation. The refilling time (mean +/- SD) in the sitting position was 40.6 +/- 10. 0 seconds, which was significantly longer (P <.001) than that measured in the supine and semirecumbent positions, 33.8 +/- 4.1 and 35.6 +/- 4.9 seconds, respectively. There was a linear relationship between the duplex scan-derived refill time (mean of 6 readings per leg) and the SCD Response device-derived refill time (r = 0.85, P <. 001). The total volume of blood (mean +/- SD) expelled per hour by the existing SCD Sequel device in the supine, semirecumbent, and sitting positions was 2.23 +/- 0.90 L/h, 2.47 +/- 0.86 L/h, and 3.28 +/- 1.24 L/h, respectively. The SCD Response device increased the volume expelled to 3.92 +/- 1.60 L/h or a 76% increase (P =.001) in the supine position, to 3.93 +/- 1.55 L/h or a 59% increase (P =. 001) in the semirecumbent position, and to 3.97 +/- 1.42 L/h or a 21% increase (P =.026) in the sitting position. By achieving more appropriately timed compression cycles over time, the new SCD Response System is effective in preventing venous stasis by means of a new method that improves on the clinically documented effectiveness of the existing SCD system. Further studies testing its potential for improved efficacy in preventing deep venous thrombosis are justified.
    Journal of Vascular Surgery 12/2000; 32(5):932-40. DOI:10.1067/mva.2000.110358 · 2.98 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The purpose of this study was to correlate the right atrial pressure with the blood flow velocity and pulsatility index (PI) values obtained with duplex Doppler sonography of the common femoral vein. Thirty consecutive patients with suspected right-sided heart failure who had right atrial pressure measurements for correlation were included in the study. The common femoral veins were examined with duplex Doppler sonography. Irrespective of the presence or absence of clinical right-sided heart failure, patients were divided into 2 groups on the basis of their right atrial pressures. The mean flow velocities and PIs in the common femoral veins of the 2 groups were compared. In patients with elevated right atrial pressure (> or = 8 mm Hg), the mean minimum flow velocity + standard deviation (-0.15 +/- 0.11 m/second) in the common femoral vein was significantly lower than that in patients with normal right atrial pressure (< 8 mm Hg) (0.01 +/- 0.10 m/second) (p < 0.001). There was no significant difference in the mean maximum flow velocities in the common femoral vein between the patients with elevated right atrial pressure (0.25 +/- 0.08 m/second) and the patients with normal right atrial pressure (0.21 +/- 0.09 m/second). The mean PI in patients with elevated right atrial pressure (7.75 +/- 3.19) was significantly higher than the mean PI in patients with normal right atrial pressure (1.55 +/- 1.30; p < 0.001). There was a weak negative correlation between the minimum flow velocity and the pressure in the right atrium in patients with elevated right atrial pressure (p = 0.05; r = -0.4760). The amplitude of retrograde waves seen in patients with normal right atrial pressure was significantly smaller than in patients with elevated right atrial pressure (p < 0.05). The association of a decreased minimum velocity, especially a negative value, and an increase in PI in the common femoral vein may indicate an elevated right atrial pressure. Sonographic assessment of retrograde flow velocity in the common femoral vein may be useful in monitoring the response to medical treatment to decrease atrial pressure.
    Journal of Clinical Ultrasound 02/2001; 29(2):87-91. DOI:10.1002/1097-0096(200102)29:2<87::AID-JCU1003>3.0.CO;2-1 · 0.80 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: A new intermittent pneumatic compression device (SCD Response System) has recently been shown in healthy volunteers to have the ability to detect the postcompression refilling of the calf veins and to respond by initiating the subsequent cycle when these veins are full. This has proven to be more effective in expelling blood proximally than the conventional intermittent pneumatic compression device (SCD Sequel System). The aim of this study was to test the influence of venous disease on the postcompression refill time detected by means of the SCD Response and the effectiveness of the new system in expelling blood in patients who have venous reflux caused by post-thrombotic syndrome or varicose veins. This open, controlled trial was conducted in an academic vascular unit with 10 patients who had post-thrombotic syndrome and 10 patients who had varicose veins. The new SCD Response System was tested against the existing SCD Sequel System in both legs in the supine, semirecumbent, and sitting positions. The refilling time sensed by means of the device was correlated with the venous filling index by using air plethysmography. The total volume of blood expelled per hour during compression was compared with that expelled by the SCD Sequel System in the same volunteers and in the same positions. An inverse association was found between the mean postcompression refilling time in the sitting position and the venous filling index of the apparently healthy or less severely affected leg (r = -0.52, P =.019), the refill time being significantly shorter in patients with advanced venous disease. The SCD Response System increased the volume expelled per hour in the post-thrombotic leg, when compared with the SCD Sequel System, by 109.9% (P =.005) in the supine position, by 85.1% (P =.009) in the semirecumbent position, and by 40.2% (P =.005) in the sitting position. The corresponding results in the more severely affected leg in patients with varicose veins were 71.9% (P =.005) in the supine position, 77.9% (P =.005) in the semirecumbent position, and 55.7% (P =.013) in the sitting position. Similar improved results were also found in the contralateral leg in both groups. The deflation settings of the new SCD Response System are able to be adjusted selectively, correlating with the physiological severity of chronic venous insufficiency. By achieving more frequent compression cycles, the new system is more effective than the current one in expelling blood proximally, confirming our earlier findings in healthy volunteers. Further studies testing a possible improved efficacy in preventing deep venous thrombosis in this high-risk group are justified.
    Journal of Vascular Surgery 12/2001; 34(5):915-22. DOI:10.1067/mva.2001.118822 · 2.98 Impact Factor