Cerebrospinal fluid seepage through polyglactin 910 dura substitute manifested as spinal extradural collection of fluid.

Division of Neurosurgery, Pula General Hospital, Pula, Croatia.
Croatian Medical Journal (Impact Factor: 1.25). 07/2000; 41(2):210-2.
Source: PubMed

ABSTRACT Following excision of pilocytic astrocytoma, a 12-year-old girl underwent posterior cranial fossa synthetic duraplasty with polyglactin 910 mesh. On the 8th postoperative day, unusual extradural collection was diagnosed by spinal magnetic resonance imaging. On the 14th postoperative day, cerebrospinal fluid leakage in the upper part of the postoperative wound was noticed. Unusual extradural collection detected by spinal magnetic resonance imaging was assumed to be the consequence of cerebrospinal fluid seepage and a warning sign of cerebrospinal fluid leakage following synthetic posterior fossa duraplasty. This case shows that polyglactin 910 mesh may be ineffective when used for posterior cranial fossa duraplasty in children, although it is considered as valuable as autologous tissue.

0 Bookmarks
 · 
106 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Primary closure of the dura remains difficult in many neurosurgical cases. One option for dural grafting is the collagen sponge, which is available in multiple forms, namely, monolayer collagen and bilayer collagen. Our primary goal was to assess differences in the incidence of postoperative cerebrospinal fluid (CSF) leak, including fistula and pseudomeningocele, and postoperative infection between monolayer collagen and bilayer collagen grafts. A single-center retrospective analysis of 475 consecutive neurosurgical procedures was performed. Primary endpoints were CSF leak and infection, adjusting for the impact of additional nonautologous materials. Multivariate regression analysis was used to identify predictors of postoperative CSF leak and infection. The overall frequency of postoperative CSF leak was 6.7%. There was no significant difference in the incidence of CSF leak based on the type of collagen sponge (monolayer versus bilayer) used (5.5% versus 7.5%, respectively; P = 0.38). The overall frequency of postoperative infection was 4.2%. There was no significant difference in the incidence of infection between groups (4.9% versus 3.8%; P = 0.54). Bilayer sponges were associated with a significantly lower incidence of CSF leak than monolayer sponges (odds ratio, 0.09; 95% confidence interval, 0.01-0.73). Bilayer collagen sponges are associated with a reduction in postoperative CSF leak, notably in posterior fossa surgery. The need for additional non-native materials is predictive of postoperative CSF leak, along with location and type of procedure. Intrinsic patient characteristics (e.g., age, diabetes, smoking) do not seem to affect the efficacy of collagen sponge dural grafts.
    Neurosurgery 11/2009; 65(5):890-7; discussion 897. · 2.53 Impact Factor

Full-text

Download
52 Downloads
Available from
Jun 2, 2014