Improved common carotid elasticity and intima-media thickness measurements from computer analysis of sequential ultrasound frames.

Department of Medicine, Division of Cardiology, Atherosclerosis Research Unit, University of Southern California School of Medicine, 2250 Alcazar Street, CSC 132, Los Angeles, CA 90033, USA.
Atherosclerosis (Impact Factor: 3.97). 02/2001; 154(1):185-93. DOI: 10.1016/S0021-9150(00)00461-5
Source: PubMed

ABSTRACT B-mode ultrasound has gained popularity as a non-invasive method for direct visualization of superficial vessels. With B-mode ultrasound, arterial stiffness can be directly measured since image acquisition of the arterial wall thickness and vessel diameter can be obtained simultaneously in a dynamic fashion throughout the cardiac cycle. Recently, a method was developed to measure carotid arterial diameter and intima-media thickness (IMT) from B-mode images that utilizes computerized edge tracking-multiframe image processing that automatically measures arterial diameter and IMT in multiple sequential frames spanning several cardiac cycles. To evaluate this method, replicate B-mode common carotid artery ultrasound examinations and blood pressure measurements were obtained in 24 subjects 1-2 weeks apart. Approximately 80 sequential frames spanning two cardiac cycles were analyzed from each ultrasound examination to obtain maximum arterial diameter (D(max)), minimum arterial diameter (D(min)), and IMT using a computerized edge detection method. The intraclass correlations of D(max), D(min), and IMT were 0.97-0.99 and the mean absolute difference for these measurements were 0.03-0.11 mm. The coefficient of variation for D(max) and D(min) were 1.28 and 1.18%, respectively. The intraclass correlation for several standard arterial stiffness indices, Peterson's elastic modulus, Young's modulus, arterial distensibility, compliance, and the beta stiffness index ranged between 0.84 and 0.89. Additionally, it was determined that averaging IMT over five frames centered at D(min) reduced single frame IMT measurement variability by 27% (P=0.005) compared with IMT measured from a single frame corresponding to D(min). Comparison of the phasic relationship of D(max) and D(min) measured from the B-mode ultrasound image with the simultaneously recorded electrocardiogram (ECG) signal in the 24 subjects, provided a more accurate method of frame selection for arterial diameter extrema independent of the ECG signal. The method of computerized edge detection-sequential multiframe image processing presented in this paper represents a technological advance for image analysis of B-mode ultrasound images of common carotid arterial dimensions that is highly reproducible and directly applicable to noninvasive imaging of atherosclerosis.

0 Followers
 · 
62 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Ultrasonic evaluation of intima-media thickness (IMT) is an early marker of assessing the development of atherosclerosis and determining cardiovascular risk. To attain the best possible diagnosis, it is essential that medical images be clear, sharp and without noise and artifacts. Comparison of speckle reducing anisotropic diffusion (SRAD), discrete (DTD) and continuum topological derivative (CTD) on B-mode ultrasound images of common carotid and brachial arteries throughout the cardiac cycle. In a cross-sectional design, an examination was performed on forty-two human subjects with a mean age of 44 ± 6 years from April 2013 to June 2013. This study was approved by the ethics committees of Kashan University of Medical Sciences and Beheshti Hospital. An ultrasonic examination of common carotid and brachial arteries of forty-two human subjects was performed. The program was designed in MATLAB software to extract consecutive B-mode images and apply region of interest (ROI) on the IMT of the common carotid and brachial arteries. Then, three different noise reduction filters with the Canny edge detection were used in ROI separately. Finally, the program measured the image quality metrics. According to values of eleven different image quality metrics (mentioned in the main text), there was a significant difference between CTD, DTD and SRAD filters with the Canny edge detection status in the common carotid and brachial arteries throughout the cardiac cycle (all P values < 0.001). For example, peak signal to noise ratios (PSNR) using CTD, DTD and SRAD filters were 95.43 ± 0.64, 88.86 ± 0.82 and 73.02 ± 0.20 in common carotid and 96.39 ± 1.25, 92.58 ± 0.11 and 88.27 ± 0.63 in brachial arteries, respectively (both P values < 0.001). By measuring image quality metrics, this study showed that DTD and CTD filters with the Canny edge detection respectively, are better than SRAD filter with the Canny detection for speckle suppression and details preservation in both arteries in the ultrasound images.
    02/2015; 17(2). DOI:10.5812/ircmj.25013
  • [Show abstract] [Hide abstract]
    ABSTRACT: Adults infected with HIV have increased atherosclerosis potentially associated with both HIV and non-HIV associated factors. We characterized risk factors for atherosclerosis as measured by noninvasive vascular imaging. We used B-mode ultrasound to examine levels and correlates of echogenicity and vessel wall thickness of the carotid artery intima-media complex in 1282 HIV-infected and 510 HIV-uninfected women of the Women's Interagency HIV Study. Levels of gray scale median (GSM, a measure of echogenicity) did not vary between HIV infection groups. In both groups, smokers had increased GSM, whereas age, diabetes, elevated blood pressure, and high BMI were associated with lower (rather than higher) GSM. Each of these non-lipid CVD risk factors, especially age and blood pressure, was also associated with higher levels of carotid artery intima-media thickness (cIMT). Higher serum triglyceride levels were associated with lower GSM in both HIV-infected and HIV-uninfected groups. Additional lipid risk factors for low GSM including high LDL cholesterol and low HDL cholesterol levels were identified in HIV uninfected but not in HIV infected women. In contrast to findings for GSM, among the lipid parameters only LDL cholesterol level had an association with cIMT, which was observed only in the HIV uninfected group. Lipid and non-lipid risk factor associations with echolucency of the carotid artery and the thickness of the common carotid artery intima-media layer suggest that these measures capture different aspects of atherosclerosis. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
    Journal of the American Heart Association 01/2015; 4(2):e001405-e001405. DOI:10.1161/JAHA.114.001405 · 2.88 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Recent reports have shown that the carotid artery wall had significant movements not only in the radial but also in the longitudinal direction during the cardiac cycle. Accordingly, the idea that longitudinal elongations could be systematically neglected for compliance estimations became controversial. Assuming a dynamic change in vessel length, the standard measurement of cross-sectional compliance can be revised. In this work, we propose to estimate a volumetric compliance based on continuous measurements of carotid diameter and intima-media thickness (IMT) from B-mode ultrasound sequences. Assuming the principle of conservation of the mass of wall volume (compressibility equals zero), a temporal longitudinal elongation can be calculated to estimate a volumetric compliance. Moreover, elongations can also be estimated allowing small compressibility factors to model some wall leakage. The cross-sectional and the volumetric compliance were estimated in 45 healthy volunteers and 19 asymptomatic patients. The standard measurement underestimated the volumetric compliance by 25% for young volunteers (p < 0.01) and 17% for patients (p < 0.05). When compressibility factors different from zero were allowed, volunteers and patients reached values of 9% and 4%, respectively. We conclude that a simultaneous assessment of carotid diameter and IMT can be employed to estimate a volumetric compliance incorporating a longitudinal elongation. The cross-sectional compliance, that neglects the change in vessel length, underestimates the volumetric compliance.
    Physiological Measurement 02/2015; 36(3):397-407. DOI:10.1088/0967-3334/36/3/397 · 1.62 Impact Factor