Detailed three-dimensional fetal echocardiography facilitated by Internet link

Department of Obstetrics and Gynaecology, Royal Free Hospital, London, UK.
Ultrasound in Obstetrics and Gynecology (Impact Factor: 3.85). 11/2001; 18(4):325-8. DOI: 10.1046/j.0960-7692.2001.00520.x
Source: PubMed


To assess whether a complete virtual cardiological examination can be achieved in stored three-dimensional volumes of the fetal heart, transmitted to a tertiary fetal cardiology center via the Internet.
Thirty sequential normal singleton pregnancies were included in the study. Four cardiac volumes were acquired using a three-dimensional ultrasound system. The volumes were sent via the Internet to a tertiary fetal cardiology center, where a detailed fetal cardiac examination was attempted using the three-dimensional volumetric dataset.
The median gestational age was 24 (range, 22-28) weeks. A complete heart examination was accomplished in 23 of 30 cases (76.7%; 95% confidence interval, 58-90%). The four-chamber view and the cardiac situs were seen in all cases. The right ventricular outflow tract was seen in 29 (96.7%) cases and the left ventricular outflow tract in 25 (83.3%) cases. The long-axis view of the aortic arch, superior vena cava, inferior vena cava and pulmonary veins were visualized in more than 80% of cases. The mean time of volume acquisition was 9.5 (standard deviation, 2.3) min and the mean examination time by the fetal cardiologist was 17 (standard deviation, 4.8) min.
These preliminary results demonstrate that a three-dimensional virtual examination of the fetal heart is possible. There are limitations such as the lack of flow and functional information but complete ascertainment of the main cardiac connections was possible in the majority of cases. The use of an Internet link has major implications, particularly for situations in which the scanning center is geographically remote from the tertiary referral center.

Download full-text


Available from: John Simpson, Oct 21, 2014
  • Source
    • "acquiring data from the fetal heart (a single, automatic volume sweep) and produces a 4D cine sequence.(Michailidis et al., 2001) A group from Chile conducted a similar study STIC transmitted across an ADSL connection with bandwidths of 300 and 600 kbps. In total fifty scans were transmitted from two peripheral hospitals to the regional centre. On average complete fetal echocardiograms could be interpreted in 92%.(Vinals et al., 2005)"

    Telemedicine Techniques and Applications, 06/2011; , ISBN: 978-953-307-354-5
  • [Show abstract] [Hide abstract]
    ABSTRACT: An approach for acquiring dimensionally accurate three-dimensional (3-D) ultrasound data from multiple 2-D image planes is presented. This is based on the use of a modified linear-phased array comprising a central imaging array that acquires multiple, essentially parallel, 2-D slices as the transducer is translated over the tissue of interest. Small, perpendicularly oriented, tracking arrays are integrally mounted on each end of the imaging transducer. As the transducer is translated in an elevational direction with respect to the central imaging array, the images obtained by the tracking arrays remain largely coplanar. The motion between successive tracking images is determined using a minimum sum of absolute difference (MSAD) image matching technique with subpixel matching resolution. An initial phantom scanning-based test of a prototype 8 MHz array indicates that linear dimensional accuracy of 4.6% (2 /spl sigma/) is achievable. This result compares favorably with those obtained using an assumed average velocity [31.5% (2 /spl sigma/) accuracy] and using an approach based on measuring image-to-image decorrelation [8.4% (2 /spl sigma/) accuracy]. The prototype array and imaging system were also tested in a clinical environment, and early results suggest that the approach has the potential to enable a low cost, rapid, screening method for detecting carotid artery stenosis. The average time for performing a screening test for carotid stenosis was reduced from an average of 45 minutes using 2-D duplex Doppler to 12 minutes using the new 3-D scanning approach.
    IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 09/2002; 49(8-49):1029 - 1038. DOI:10.1109/TUFFC.2002.1026015 · 1.51 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: A total of 15 fetuses were scanned using 2-D array volumetric ultrasound (US). Acquired cardiac data were converted for rendering dynamic 3-D surface views and reformatting cross-sectional views. The image usefulness was compared between the data obtained from subcostal/subxiphoid and other imaging windows; the former are usually free of acoustic shadowing. Of 60 data sets recorded, 12 (20%) were acquired through subcostal windows in 6 (40%) patients. Subcostal windows were unavailable from the remaining patients due to unfavourable fetal positions. Of the 12 sets, 6 (50%) provided the dynamic 3-D and/or cross-sectional views of either the entire fetal heart or a great portion of it for sufficient assessments of its major structures and their spatial relationships. Of 48 data sets from other windows, only 9 (19%) provided such 3-D and/or cross-sectional views; the lower rate being due to acoustic shadowing. Real-time 3-D US is a convenient method for volumetric data acquisition. Through subcostal windows, useful information about the spatial relationships between major cardiac structures can be acquired. However, to offer detailed information, considerable improvement in imaging quality is needed.
    Ultrasound in Medicine & Biology 10/2002; 28(9):1099-105. DOI:10.1016/S0301-5629(02)00560-4 · 2.21 Impact Factor
Show more