X-ray computed tomography methods for in vivo evaluation of local drug release systems.

Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.
IEEE Transactions on Medical Imaging (Impact Factor: 4.03). 11/2002; 21(10):1310-6. DOI: 10.1109/TMI.2002.806270
Source: PubMed

ABSTRACT Recent advances in drug delivery techniques have necessitated the development of tools for in vivo monitoring of drug distributions. Gamma emission imaging and magnetic resonance imaging suffer from problems of resolution and sensitivity, respectively. We propose that the combination of X-ray CT imaging and image analysis techniques provides an excellent method for the evaluation of the transport of platinum-containing drugs from a localized, controlled release source. We correlated local carboplatin concentration with CT intensity, producing a linear relationship with a sensitivity of 62.6 microg/mL per Hounsfield unit. As an example application, we evaluated the differences in drug transport properties between normal and ablated rabbit liver from implanted polymer millirods. The use of three-dimensional visualization provided a method of evaluating the placement of the drug delivery device in relation to the surrounding anatomy, and registration and reformatting allowed the accurate comparison of the sequence of temporal CT volumes acquired over a period of 24 h. Taking averages over radial lines extending away from the center of the implanted millirods and integrating over clinically appropriate regions, yielded information about drug release from the millirod and transport in biological tissues. Comparing implants in normal and ablated tissues, we found that ablation prior to millirod implantation greatly decreased the loss of drug from the immediate area, resulting in a higher average dose to the surrounding tissue. This work shows that X-ray CT imaging is a useful technique for the in vivo evaluation of the pharmacokinetics of platinated agents.

0 Bookmarks
 · 
86 Views
  • Journal of The Electrochemical Society - J ELECTROCHEM SOC. 01/2005; 152(1).
  • [Show abstract] [Hide abstract]
    ABSTRACT: We created a method for three-dimensional registration of medical scanner image volumes to images of physical tissue sections or other volumes, and evaluated its accuracy. The method is applicable for many animal experiments, and we are applying it to evaluate interventional MRI imaging of thermal ablation and to quantify in vivo drug release from a new device for localized, controlled release. The method computes an optimum set of rigid body registration parameters by iterative minimization of the Euclidean distances between automatically generated correspondence points, along manually selected fiducial needle paths, and optional point landmarks. For numerically simulated registrations, using two needle paths over a range of needle orientations, median voxel displacement errors depended only on needle localization error when the angle between needles was at least 15 degrees. For parameters typical of our in vivo experiments, the median error was
    Proc SPIE 05/2002;
  • [Show abstract] [Hide abstract]
    ABSTRACT: The registration of 2D and 3D images is one of the key tasks in medical image processing and analysis. Accurate registration is a crucial preprocessing step for many tasks; consequently, the evaluation of its accuracy becomes necessary. Unfortunately, this is a difficult task, especially when no golden pattern (true result) is available and when the signal values may have changed between successive images to be registered. This is the case this paper deals with: we have a series of 3D images, magnetic resonance images (MRI) of the liver and adjacent areas that have to be registered. They have been taken while a contrast is diffused through the liver tissue, so intensity of each observed point changes for two reasons: contrast diffusion/perfusion and deformation of the liver (due to body movement and breathing). In this paper, we introduce a new method to automatically compare two or more registration algorithms applied to the same case of a perfusion magnetic resonance dynamic image so that the best of them can be chosen when no ground truth is available. This is done by modeling the function that gives the intensity at a given point as a functional datum, and using statistical techniques to assess its change in comparison with other functions. An example of the application is shown by comparing two parametrizations of a B-spline based registration algorithm. The main result of the proposed method is a suggestive evidence to guide the physician in the process of selecting a registration algorithm, that recommends the algorithm of minimal complexity but still suitable for the case to be analyzed.
    Computer methods and programs in biomedicine 06/2012; · 1.56 Impact Factor

Full-text (2 Sources)

Download
66 Downloads
Available from
May 16, 2014