X-ray computed tomography methods for in vivo evaluation of local drug release systems

Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.
IEEE Transactions on Medical Imaging (Impact Factor: 3.8). 11/2002; 21(10):1310-6. DOI: 10.1109/TMI.2002.806270
Source: IEEE Xplore

ABSTRACT Recent advances in drug delivery techniques have necessitated the development of tools for in vivo monitoring of drug distributions. Gamma emission imaging and magnetic resonance imaging suffer from problems of resolution and sensitivity, respectively. We propose that the combination of X-ray CT imaging and image analysis techniques provides an excellent method for the evaluation of the transport of platinum-containing drugs from a localized, controlled release source. We correlated local carboplatin concentration with CT intensity, producing a linear relationship with a sensitivity of 62.6 microg/mL per Hounsfield unit. As an example application, we evaluated the differences in drug transport properties between normal and ablated rabbit liver from implanted polymer millirods. The use of three-dimensional visualization provided a method of evaluating the placement of the drug delivery device in relation to the surrounding anatomy, and registration and reformatting allowed the accurate comparison of the sequence of temporal CT volumes acquired over a period of 24 h. Taking averages over radial lines extending away from the center of the implanted millirods and integrating over clinically appropriate regions, yielded information about drug release from the millirod and transport in biological tissues. Comparing implants in normal and ablated tissues, we found that ablation prior to millirod implantation greatly decreased the loss of drug from the immediate area, resulting in a higher average dose to the surrounding tissue. This work shows that X-ray CT imaging is a useful technique for the in vivo evaluation of the pharmacokinetics of platinated agents.

Download full-text

Full-text

Available from: Agata Exner, Jul 28, 2015
1 Follower
 · 
106 Views
  • Source
    • "In general, the more needle paths are utilized, the smaller the influence of a given needle's orientation and localization uncertainty on registration . As described previously, although the method was developed for evaluation of thermal ablation, it is useful for other animal experiments including the in vivo measurement of drug pharmacokinetics [10]. Some variations on the method were considered. "
    [Show abstract] [Hide abstract]
    ABSTRACT: We created a method for three-dimensional (3-D) registration of medical images (e.g., magnetic resonance imaging (MRI) or computed tomography) to images of physical tissue sections or to other medical images and evaluated its accuracy. Our method proved valuable for evaluation of animal model experiments on interventional-MRI guided thermal ablation and on a new localized drug delivery system. The method computes an optimum set of rigid body registration parameters by minimization of the Euclidean distances between automatically chosen correspondence points, along manually selected fiducial needle paths, and optional point landmarks, using the iterative closest point algorithm. For numerically simulated experiments, using two needle paths over a range of needle orientations, mean voxel displacement errors depended mostly on needle localization error when the angle between needles was at least 20 degrees. For parameters typical of our in vivo experiments, the mean voxel displacement error was < 0.35 mm. In addition, we determined that the distance objective function was a useful diagnostic for predicting registration quality. To evaluate the registration quality of physical specimens, we computed the misregistration for a needle not considered during the optimization procedure. We registered an ex vivo sheep brain MR volume with another MR volume and tissue section photographs, using various combinations of needle and point landmarks. Mean registration error was always < or = 0.54 mm for MR-to-MR registrations and < or = 0.52 mm for MR to tissue section registrations. We also applied the method to correlate MR volumes of radio-frequency induced thermal ablation lesions with actual tissue destruction. In this case, in vivo rabbit thigh volumes were registered to photographs of ex vivo tissue sections using two needle paths. Mean registration errors were between 0.7 and 1.36 mm over all rabbits, the largest error less than two MR voxel widths. We conclude that our method provides sufficient spatial correspondence to facilitate comparison of 3-D image data with data from gross pathology tissue sections and histology.
    IEEE Transactions on Medical Imaging 06/2003; 22(5):653-60. DOI:10.1109/TMI.2003.812246 · 3.80 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: A noncontact, biologically safe imaging system for measuring surface area and volume is described. It uses a technique known as structured light, a method in which the surfaces of 3-D objects are measured by projecting a regular geometric pattern onto its surface and viewing the illuminated surface using one or more cameras at different angles. The 3-D locations of points on the surface of the skin are reconstructed from the structured light, and the region of interest is segmented. After the reconstructed 3-D locations and the segmented image are combined, cubic spline interpolation is used to represent the space curves and bicubic surface patches to represent the surface area. Gaussian quadrature double integration is used to calculate the surface area. The steps necessary to do the segmentation, curve and patch representation, and surface area computation are outlined. It is found that the surface area estimates are as accurate as estimates based on visual inspection
    Engineering in Medicine and Biology Society, 1989. Images of the Twenty-First Century., Proceedings of the Annual International Conference of the IEEE Engineering in; 12/1989
  • [Show abstract] [Hide abstract]
    ABSTRACT: We created a method for three-dimensional registration of medical scanner image volumes to images of physical tissue sections or other volumes, and evaluated its accuracy. The method is applicable for many animal experiments, and we are applying it to evaluate interventional MRI imaging of thermal ablation and to quantify in vivo drug release from a new device for localized, controlled release. The method computes an optimum set of rigid body registration parameters by iterative minimization of the Euclidean distances between automatically generated correspondence points, along manually selected fiducial needle paths, and optional point landmarks. For numerically simulated registrations, using two needle paths over a range of needle orientations, median voxel displacement errors depended only on needle localization error when the angle between needles was at least 15 degrees. For parameters typical of our in vivo experiments, the median error was
    Proceedings of SPIE - The International Society for Optical Engineering 05/2002; DOI:10.1117/12.466956 · 0.20 Impact Factor
Show more