Article

Effectiveness of implantable defibrillators for preventing arrhythmic events and death

University of Toronto, Department of Health Policy, Management and Evaluation/Clinical Epidemiology, Toronto, Canada.
Journal of the American College of Cardiology (Impact Factor: 15.34). 05/2003; 41(9):1573-82. DOI: 10.1016/S0735-1097(03)00253-5
Source: PubMed

ABSTRACT The aim of this study was to compare the effectiveness of the implantable cardioverter defibrillator (ICD) and medical strategies for prevention of arrhythmic events and death.
The ICD is a potential strategy to reduce mortality in patients at risk of sudden death.
The MEDLINE, EMBASE, and Cochrane Library electronic databases were searched from January 1966 to April 2002. All published randomized controlled trials comparing ICD implantation with medical therapy were reviewed. Four independent reviewers extracted data on all-cause mortality, nonarrhythmic death, and arrhythmic death using a standardized protocol.
Nine studies including over 5,000 patients were synthesized using both fixed-effects and random-effects models. The primary and secondary prevention trials showed a significant benefit of the ICD with respect to arrhythmic death, with relative risks (RR) of 0.34 and 0.50, respectively (both p < 0.001). The mortality benefit of the ICD was entirely attributable to a reduction in arrhythmic death (all trials: p < 0.00001). Whereas the secondary prevention trials exhibited a robust decrease in all-cause ICD mortality (RR 0.75; p < 0.001), the pooled primary prevention trials demonstrated decreased all-cause ICD mortality (RR 0.66; p < 0.05) which was dependent on selected individual trials. The disparity in ICD-related mortality reductions in the primary prevention trials was related to variability in the incidence of arrhythmic death between individual studies.
Although the ICD decreases the risk of arrhythmic death, its impact on all-cause mortality is related to the underlying risk of arrhythmia-related death relative to competing causes. Given the cost of the device strategy, policies of targeted intervention based on the future risk of arrhythmia are warranted.

Full-text

Available from: Peter P Liu, May 10, 2014
0 Followers
 · 
64 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The risk of sudden cardiac death (SCD) is high in chronic kidney disease patients, and it increases with the progression of kidney function deterioration. The most common causes of SDC are the following: ventricular tachycardia, ventricular tachyarrhythmia, tachycardia torsade de pointes, sustained ventricular fibrillation and bradyarrhythmia. Dialysis influences cardiovascular system and results in hemodynamic disturbances as well as electrolyte shifts altering myocardial electrophysiology. Studies suggest that this procedure exerts both detrimental (poor volume control can exacerbate hypertension and left ventricle hypertrophy) and beneficial effects (associated with fluid removal and subsequent decrease in left ventricle stretch). Dialysis-related vulnerability to serious arrhythmias is the result of sudden shifts in fluid status and electrolytes, particularly potassium, which alter the physiological milieu. Also Ca(2+) ions, in which concentration alters during dialysis, are of key importance in the contraction of vascular smooth muscle cells and cardiac myocytes, thus exerting significant effects on hemodynamics. Due to the fact that SCD occurs with similar frequency in peritoneal dialysis and in hemodialysis patients, it seems that end-stage renal disease factors are more important than the specific ones associated with dialysis type. The results of randomized trials suggested that hemodialysis patients may not derive the same benefit of cardiovascular disease therapy including beta-blockers, calcium channel blockers and angiotensin-converting enzyme inhibitors as the general population with normal kidney function. Noninvasive tests used to stratify SCD risk in HD patients have poor positive value, and thus, combining tests including HRV, baroreceptor sensitivity and effectiveness index as well as its function indices and heart rate turbulence should be implemented. There are only few large randomized placebo-controlled trials assessing the influence of cardioprotective medications or implantable cardioverter defibrillator (ICD) implantation in dialysis patients on life quality and survival, and their results are sometimes contradictory. The decision concerning treatment and/or ICD implantation in this group of patients should be made on the basis of careful assessment of individual risk factors. Moreover, due to the high hazard of cardiovascular mortality including SCD in dialysis patients, physicians should concentrate on the early selection of high-risk patients, monitoring them and introduction of preventive measures.
    International Urology and Nephrology 05/2015; DOI:10.1007/s11255-015-0994-0 · 1.29 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Background:Defibrillation testing (DT) is considered a standard procedure during implantable cardioverter-defibrillator (ICD) implantation. However, little is known about the factors that are significantly related to patients with high defibrillation threshold (DFT) using the present triad system.Methods and Results:We examined 286 consecutive patients who underwent ICD implantation with a transvenous dual-coil lead and DT from December 2000 to December 2011. We defined patients who required 25 J or more by the implanted device as the high DFT group, and those who required less than 25 J as the normal DFT group. For each patient, assessment parameters included underlying disease, comorbidities, NYHA functional class, drugs, and echocardiographic measures. The high DFT group consisted of 12 patients (4.2%). Multivariate analysis identified 3 independent predictors for high DFT: atrial fibrillation (odds ratio (OR) 4.85, 95% confidence interval (CI) 1.24-22.33, P=0.023), hypertension (OR 4.01, 95% CI 1.08-15.96, P=0.039), thickness of interventricular septum (IVS) >12 mm (OR 4.82, 95% CI 1.17-20.31, P=0.030).Conclusions:Atrial fibrillation, hypertension and IVS hypertrophy were significantly associated with high DFT. Identification of such patients could help to lower the risk of complications with DT.
    Circulation Journal 11/2014; 79(1). DOI:10.1253/circj.CJ-14-0860 · 3.69 Impact Factor
  • Source
    Kardiologia polska 01/2014; 72(11):1054-126. DOI:10.5603/KP.2014.0212 · 0.52 Impact Factor