Publications (2) View all
-
Article: Design and validation of the Grip-ball for measurement of hand grip strength.
Rana Jaber, David J Hewson, Jacques Duchêne[show abstract] [hide abstract]
ABSTRACT: The Grip-ball is a new dynamometer used to evaluate grip strength, as well as for use in home-based rehabilitation of the hand and forearm. The Grip-ball consists of pressure and temperature sensors and an electronic wireless communication system contained in an airtight ball. That can be inflated to different pressures. The device has advantages over standard dynamometers in that it looks like a simple ball, and can wirelessly communicate via Bluetooth to any compatible receiver, thus have potential to be used for clinical assessment and rehabilitation in a remote setting. The reliability and reproducibility of the device were assessed for the pressure sensor itself, as well as the relationship between the force applied and the pressure measured by the Grip-ball. The initial validation was performed using the pressure sensor without the ball in order to confirm the accuracy of the sensor used. A second validation study was conducted using the Grip-ball rather than just its sensor to examine the relationship between the pressure measured inside the ball and force applied. The results showed that there is a very good correlation (r=0.997, p<0.05) between the pressure measured by the Grip-ball sensor and that measured by a Vigorimeter, thus confirming the reliability of the sensor used in the Grip-ball. A quadratic regression equation was calculated in order to predict the force applied based on the pressure measured inside the ball, and the initial pressure to which the ball was inflated (R(2)=0.97, standard error 10.9N). Such a finding compares favourably with the variability inherent in Jamar recordings, thus indicating that the Grip-ball could be used to assess grip force. An industrial version of the Grip-ball, which is currently under development, will be able to be used for the entire range of grip force in the population.Medical Engineering & Physics 08/2012; 34(9):1356-61. · 1.62 Impact Factor -
Article: Reliability and validity of the Grip-Ball dynamometer for grip-strength measurement.
[show abstract] [hide abstract]
ABSTRACT: Grip-strength measurement is a key element in the evaluation of numerous conditions including frailty. An innovative grip-strength evaluation tool, the Grip-Ball has been developed for remote assessment of grip-strength. The Grip-Ball is an airtight ball that can be inflated to different pressures, thus varying the stiffness of the ball and the grip-strength dynamics. Three different initial pressures of 100, 125, and 150 kPa were evaluated in respect to reliability and validity, when compared to the Jamar. Reliability was very high, with ICC values of 0.95, 0.98, and 0.99 for 100, 125, and 150 kPa, respectively. The new device was highly correlated with the force measured using the Jamar for all initial pressures (r= 0.88, 0.93, and 0.93 for 100, 125, and 150 kPa, respectively). The possibility of varying the initial pressure would enable the Grip-Ball to be used for standard grip-strength testing and rehabilitation, while still maintaining high reliability and validity.Conference proceedings: ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 08/2012; 2012:1996-9.