Publications (50) View all
-
Article: Reconstructive endovascular treatment of fusiform or ultrawide-neck circumferential aneurysms with multiple overlapping enterprise stents and coiling.
[show abstract] [hide abstract]
ABSTRACT: Fusiform aneurysms and ultrawide-neck circumferential aneurysms are still some of the most challenging lesions. The aim of this study was to investigate the efficacy and feasibility of the use of multiple overlapping Enterprise stents with coiling for the treatment of fusiform or ultrawide-neck circumferential aneurysms. Twelve consecutive patients (9 men and 3 women; mean age, 56 years) with fusiform (n = 5) or ultrawide-neck circumferential (n = 7) aneurysms were treated with 2-3 overlapping Enterprise stents and coiling. The feasibility of this procedure and the clinical and angiographic outcomes of this technique were retrospectively evaluated. All patients were successfully treated by using this technique without any complications. Posttreatment angiographic results revealed grade 4 occlusion of the aneurysm in 6, grade 3 in 4, and grade 2 in 2 patients. Clinical follow-up was performed in all patients (mean, 16 months; range, 5-24 months). Nine patients had an mRS score of 0. Two had an mRS score of 1, one of whom had an initial mRS score of 2 due to the mass effect of a giant aneurysm; the other had a recurrent aneurysm presenting with SAH 5 years after clipping. Angiographic follow-up was performed in 10 patients at 6-20 months posttreatment. Nine had stable or improved occlusion, while 1 had a minor recurrence. In this small series, multiple overlapping Enterprise stents with coiling were a feasible and effective option for the treatment of fusiform and ultrawide-neck circumferential aneurysms. Further experience and follow-up are required to document the long-term efficacy of this treatment.American Journal of Neuroradiology 01/2012; 33(5):965-71. · 2.93 Impact Factor -
Article: Embolization of intracranial aneurysms with HydroSoft coils: results of the Korean multicenter study.
[show abstract] [hide abstract]
ABSTRACT: Various modifications of detachable coils have been attempted to reduce recurrence rates in aneurysmal coil embolization and HydroSoft coil is one of them. The authors report their experience using HydroSoft coils in the treatment of cerebral aneurysms. The present study is a prospective multicenter observational series of 127 aneurysms in 120 patients treated with HydroSoft coils. Ten centers participated in this study, and there were 92 (72%) unruptured and 35 ruptured aneurysms. Aneurysm volumes were ≥ 100 mm³ in 21 (17%) and < 100 mm³ in 106 (83%) (mean, 56 mm³; range, 5-249 mm³). The average percentage length of HydroSoft coils detached in treated aneurysms was 67% (range, 42%-100%). Immediate postprocedural angiography demonstrated complete aneurysm occlusion in 69% (87/127 aneurysms), residual neck in 20% (25/127), and residual sac in 12% (15/127). Procedure-related adverse events occurred in 4.7% (6/127 aneurysms), including procedural bleeding (5/127) and thromboembolism (2/127), and immediate procedure-related morbidity and mortality rates were 0.8% and 0%. Conventional angiography or MRA follow-up was performed in 83% (105/127) at ≥ 6 months after treatment (mean interval, 11 months; range, 6-24 months). The overall recanalization rate was 3% (3/105 aneurysms; 2 major and 1 minor recanalizations). Progression to complete aneurysmal occlusion was noted in 20 of 27 aneurysms (74%) during the follow-up. The safety profile of HydroSoft coils appears acceptable. In terms of initial occlusion rates and durability, embolization by using HydroSoft coils seems to be favorable compared with most large series of pure platinum or coated coils.American Journal of Neuroradiology 09/2011; 32(9):1756-61. · 2.93 Impact Factor -
Article: Emergent self-expanding stent placement for acute intracranial or extracranial internal carotid artery dissection with significant hemodynamic insufficiency.
[show abstract] [hide abstract]
ABSTRACT: ICAD with hemodynamic insufficiency may present with either fulminant infarct or with progressive neurologic deterioration. The purpose of this study was to evaluate the safety and efficacy of emergent self-expanding stent placement for acute intracranial or extracranial ICAD with significant hemodynamic insufficiency. Eight patients (7 men and 1 woman; age range, 20-55 years; NIHSS score, 5-21) underwent emergent self-expanding stent placement for treatment of significant hemodynamic insufficiency due to acute ICAD. The safety and efficacy of emergent self-expanding stent placement were retrospectively evaluated. All patients presented with progressive (n = 6) or fluctuating (n = 2) neurologic deficits and revealed markedly decreased perfusion on CT or MR perfusion studies. Conventional angiography revealed acute occlusion (n = 2) or critical stenosis (n = 6) in intracranial (n = 3) or extracranial (n = 5) carotid arteries with a lack of sufficient collaterals. Stent placement was successful in all patients without any procedure-related complications. In all patients, hemodynamic insufficiency was corrected immediately after stent placement, and neurologic symptoms were completely resolved during several days. Mean improvement of the NIHSS score between baseline and discharge was 11.6 (range, 5-21). All patients remained neurologically intact (mRS, 0) during clinical follow-up for a mean of 21 months (range, 8-50 months). Angiographic follow-up was available for 6 patients at 3-12 months. None of the 6 patients revealed residual or in-stent restenosis. Self-expanding stent placement is a safe and effective option for selected patients with significant hemodynamic insufficiency due to acute intracranial or extracranial ICAD.American Journal of Neuroradiology 09/2010; 31(8):1529-32. · 2.93 Impact Factor -
Article: Prevalence and appearance of the posterior wall defects of the temporal bone caused by presumed arachnoid granulations and their clinical significance: CT findings.
[show abstract] [hide abstract]
ABSTRACT: Arachnoid granulations (AGs) of the posterior wall of the temporal bone are a rare cause of spontaneous CSF leakage. The purpose of this study was to investigate the prevalence and appearance of presumed AGs, evidenced by the posterior wall defects of the temporal bone with lobulated or scalloped margins on CT scans. We retrospectively reviewed CT scans of the temporal bone obtained in 1255 patients (573 men and 682 women; mean age, 42 years). We evaluated the prevalence, multiplicity, size, and location of presumed AGs in the posterior wall of the temporal bone. Preservation of the posterior wall of the mastoid air cells was also investigated and correlated with clinical features. Thirty patients (2.4%), including 13 men and 17 women, aged 27-88 years (mean, 55 years), showed a total of 40 presumed AGs on CT scans. Their prevalence tended to increase with age. They were most commonly located at the lateral third of the temporal bone at a level of or above the common crus. Although 15 lesions in 11 patients also caused focal loss of the posterior wall of the mastoid air cells, symptomatic CSF leakage was found in only 2 patients, in both of whom the adjacent mastoid air cells were also opacified on CT scans. Although rare, radiologists need to be familiar with the posterior wall defects of the temporal bone caused by presumed AGs on CT scans, because they might cause CSF leakage.American Journal of Neuroradiology 08/2008; 29(9):1704-7. · 2.93 Impact Factor -
Article: Sinonasal organized hematoma: CT and MR imaging findings.
[show abstract] [hide abstract]
ABSTRACT: Sinonasal organized hematoma (OH) is an uncommon, nonneoplastic benign condition that can be locally aggressive. The purpose of this work was to characterize the CT and MR imaging findings of sinonasal OH. CT (n = 11) and MR (n = 10) images of 12 patients (9 men and 3 women; mean age, 41 years; range, 12-76 years) with pathologically proved sinonasal OH were retrospectively reviewed. Particular attention was put on the location, shape, size, extent, internal architecture, and enhancement pattern of the lesion and associated sinus wall change. The lesions were seen as an expansile (n = 9) or nonexpansile (n = 3) mass, ranging in size from 2.2 to 6.0 cm (mean, 4.2 cm), primarily involving the maxillary sinus (n = 11) or nasal cavity (n = 1) unilaterally. The ipsilateral nasal cavity was also involved in 9 of 11 maxillary sinus lesions. Smooth sinus wall erosion other than the medial maxillary sinus wall was noted in 8 lesions. The internal architecture was best displayed on T2-weighted MR images on which all of the lesions were seen as a mixture of marked heterogeneous hypointensity and isointensity, surrounded by a hypointense peripheral rim, reflecting histologic heterogeneity of the lesion composed of hemorrhage, fibrosis, and neovascularization. Marked irregular nodular, papillary, or frondlike enhancement at the areas of neovascularization was also a typical finding seen in all of the lesions. An expansile soft tissue mass, smooth sinus wall erosion, marked heterogeneous signal intensity with a hypointense peripheral rim on T2-weighted MR images, and marked irregular nodular, papillary, or frondlike enhancement are characteristic CT and MR imaging findings of sinonasal OH.American Journal of Neuroradiology 07/2008; 29(6):1204-8. · 2.93 Impact Factor