Topics (4)

Publications (40) View all

  • Source
    Article: Magnetic Resonance Measurement of Turbulent Kinetic Energy for the Estimation of Irreversible Pressure Loss in Aortic Stenosis.
    [show abstract] [hide abstract]
    ABSTRACT: OBJECTIVES: The authors sought to measure the turbulent kinetic energy (TKE) in the ascending aorta of patients with aortic stenosis and to assess its relationship to irreversible pressure loss. BACKGROUND: Irreversible pressure loss caused by energy dissipation in post-stenotic flow is an important determinant of the hemodynamic significance of aortic stenosis. The simplified Bernoulli equation used to estimate pressure gradients often misclassifies the ventricular overload caused by aortic stenosis. The current gold standard for estimation of irreversible pressure loss is catheterization, but this method is rarely used due to its invasiveness. Post-stenotic pressure loss is largely caused by dissipation of turbulent kinetic energy into heat. Recent developments in magnetic resonance flow imaging permit noninvasive estimation of TKE. METHODS: The study was approved by the local ethics review board and all subjects gave written informed consent. Three-dimensional cine magnetic resonance flow imaging was used to measure TKE in 18 subjects (4 normal volunteers, 14 patients with aortic stenosis with and without dilation). For each subject, the peak total TKE in the ascending aorta was compared with a pressure loss index. The pressure loss index was based on a previously validated theory relating pressure loss to measures obtainable by echocardiography. RESULTS: The total TKE did not appear to be related to global flow patterns visualized based on magnetic resonance-measured velocity fields. The TKE was significantly higher in patients with aortic stenosis than in normal volunteers (p < 0.001). The peak total TKE in the ascending aorta was strongly correlated to index pressure loss (R(2) = 0.91). CONCLUSIONS: Peak total TKE in the ascending aorta correlated strongly with irreversible pressure loss estimated by a well-established method. Direct measurement of TKE by magnetic resonance flow imaging may, with further validation, be used to estimate irreversible pressure loss in aortic stenosis.
    JACC. Cardiovascular imaging 01/2013; 6(1):64-71. · 14.29 Impact Factor
  • Article: Prediction of hemodynamic severity of coarctation: a magnetic resonance imaging based prediction tree
    Journal of Cardiovascular Magnetic Resonance 05/2012; 13:1-2. · 3.72 Impact Factor
  • Article: Correlation of calcification on excised aortic valves by micro-computed tomography with severity of aortic stenosis.
    [show abstract] [hide abstract]
    ABSTRACT: The quantification of incidentally found aortic valve calcification on computed tomography (CT) is not performed routinely, as data relating to the accuracy of aortic valve calcium for estimating the severity of aortic stenosis (AS) is neither consistent nor validated. As aortic valve calcium quantification by CT is confounded by wall and coronary ostial calcification, as well as motion artifact, the ex-vivo micro-computed tomography (micro-CT) of stenotic aortic valves allows a precise measurement of the amounts of calcium present. The study aim, using excised aortic valves from patients with confirmed AS, was to determine if the amount of calcium on micro-CT correlated with the severity of AS. Each of 35 aortic valves that had been excised from patients during surgical valve replacement were examined using micro-CT imaging. The amount of calcium present was determined by absolute and proportional values of calcium volume in the specimen. Subsequently, the correlation between calcium volume and preoperative mean aortic valve gradient (MAVG), peak transaortic velocity (V(max)), and aortic valve area (AVA) on echocardiography, was evaluated. The mean calcium volume across all valves was 603.2 +/- 398.5 mm3, and the mean ratio of calcium volume to total valve volume was 0.36 +/- 0.16. The mean aortic valve gradient correlated positively with both calcium volume and ratio (r = 0.72, p < 0.001). V(max) also correlated positively with the calcium volume and ratio (r = 0.69 and 0.76 respectively; p < 0.001). A logarithmic curvilinear model proved to be the best fit to the correlation. A calcium volume of 480 mm3 showed sensitivity and specificity of 0.76 and 0.83, respectively, for a diagnosis of severe AS, while a calcium ratio of 0.37 yielded sensitivity and specificity of 0.82 and 0.94, respectively. A radiological estimation of calcium amount by volume, and its proportion to the total valve volume, were shown to serve as good predictive parameters for severe AS. An estimation of the calcium volume may serve as a complementary measure for determining the severity of AS when aortic valve calcification is identified on CT imaging.
    The Journal of heart valve disease 05/2012; 21(3):320-7. · 0.81 Impact Factor
  • Article: Response.
    Journal of Magnetic Resonance Imaging 04/2012; 36(2):507. · 2.70 Impact Factor
  • Article: MR evaluation of tetralogy of Fallot patients after surgical repair: relationship between aortic dilation and aortic regurgitation.
    Journal of Cardiovascular Magnetic Resonance 02/2012; 14 Suppl 1:P112. · 3.72 Impact Factor

Following (21) See all

Followers (15) See all