Topics (6)

Publications (49) View all

  • Article: Cardiovascular Magnetic Resonance Demonstrates Reversible Atrial Dysfunction After Catheter Ablation of Persistent Atrial Fibrillation.
    [show abstract] [hide abstract]
    ABSTRACT: INTRODUCTION: There is a paucity of data on atrial injury following ablation of persistent atrial fibrillation (AF). This study aimed at assessing reversibility of atrial dysfunction after successful persistent AF ablation using cardiovascular magnetic resonance (CMR). METHODS AND RESULTS: CMR was performed during sinus rhythm (SR) in 20 consecutive patients with persistent AF at baseline (BL) within 24 hours after ablation and after 6-month follow-up (FU). Catheter ablation included atrial substrate modification using the stepwise approach following pulmonary vein isolation (PVI) in order to attempt termination of persistent AF. Active left (LA) and right atrial (RA) function were quantified by calculating the active emptying fraction (AEF) from transvalvular flow profiles using velocity encoded (VENC) CMR. LA appendage (LAA) function was quantified by measurements of peak a-wave velocities from flow profiles perpendicular to the LAA orifice. Peri-atrial edema was assessed using black-blood T2 -weighted CMR. A significant improvement was found in LA-AEF from 18 (12-26)% at BL to 25 (22-35)% at FU (P = 0.0001). Furthermore, RA-AEF significantly increased from 31 (19-35)% at BL to 40 (35-51)% at FU (P < 0.0001). A significant improvement was also found for LAA a-wave velocities from 45 (31-65) cm/s at BL to 62 (49-75) cm/s at FU (P < 0.01). The area of peri-atrial edema on T2 -weighted CMR decreased from 1393 (1098-1797) mm(2) at BL to 24 (1-92) mm(2) at FU (P < 0.0001). CONCLUSION: CMR demonstrates reversibility of LA, LAA, and RA dysfunction associated with resorption of peri-atrial edema in patients with SR after persistent AF ablation.
    Journal of Cardiovascular Electrophysiology 02/2013; · 3.06 Impact Factor
  • Article: Precision of pulmonary vein diameter measurements assessed by CE-MRA and steady-state-free precession imaging.
    [show abstract] [hide abstract]
    ABSTRACT: OBJECTIVE: Pulmonary vein (PV) diameter assessment is important for planning and follow-up of PV ablation in atrial fibrillation. Therefore, the aim of our study was to evaluate inter- and intraobserver reliability of PV diameter measurements by contrast-enhanced magnetic resonance angiography (CE-MRA) and ECG-gated 2D multislice unenhanced steady-state-free precession sequences (multislice SSFP). METHODS: Sixty PV diameters in 17 consecutive patients were measured in transverse and coronal orientation with CE-MRA and multislice SSFP by two observers. Statistics to evaluate inter- and intraobserver reliability included Bland-Altman analysis and F-test. RESULTS: Intraobserver limits of agreement (LAG) ranged between ±0.50 cm (transverse) and ±0.86 cm (coronal) for CE-MRA versus ±0.40 cm (transverse) and ±0.67 cm (coronal) for multislice SSFP. Interobserver agreement showed LAG ranging between ±0.59 cm (transverse) and ±0.83 cm (coronal) for CE-MRA versus ±0.34 cm (transverse) and ±0.75 cm (coronal) for multislice SSFP. Intra- and interobserver variances did not reveal significant differences between CE-MRA and multislice SSFP in any orientation (all p-values >0.05). CONCLUSION: Multislice SSFP and CE-MRA enable comparable precision of PV diameter measurements. However, both methods reveal a wide range of intra- and interobserver agreement, which has to be thoroughly considered in clinical use. KEY POINTS : • Unenhanced magnetic resonance imaging can now provide measurement of pulmonary vein diameters • Steady-state-free precession offers a new method of performing unenhanced MR imaging • Both unenhanced and enhanced MRI measurements show wide intra- and interobserver variation • PV diameter measurements assessed by MRI have to be interpreted with care • Nevertheless, unenhanced MRI might replace some CT examinations for pulmonary vein demonstration.
    European Radiology 12/2012; · 3.22 Impact Factor
  • Conference Proceeding: Automatische Detektion von Aneurysmen in 3D Time-of-Flight Magnetresonanzangiographie Datensätzen
    Informatik 2012, 42. Jahrestagung der Gesellschaft für Informatik e.V. (GI); 09/2012
  • Article: Assessment of anemia during CT pulmonary angiography.
    [show abstract] [hide abstract]
    ABSTRACT: OBJECTIVES: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. MATERIAL AND METHODS: 150 consecutive patients (median age 64±16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. RESULTS: HU measurements revealed high intra- and interrater reliability (ICC>0.981 and ICC>0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r=0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. CONCLUSION: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.
    European journal of radiology 08/2012; · 2.65 Impact Factor
  • Article: Velocity encoded cardiovascular magnetic resonance to assess left atrial appendage emptying.
    [show abstract] [hide abstract]
    ABSTRACT: The presence of impaired left atrial appendage (LAA) function identifies patients who are prone to thrombus formation in the LAA and therefore being at high risk for subsequent cardioembolic stroke. LAA function is typically assessed by measurements of LAA emptying velocities using transesophageal echocardiography (TEE) in clinical routine. This study aimed at evaluating the feasibility of assessing LAA emptying by velocity encoded (VENC) cardiovascular magnetic resonance (CMR). This study included 30 patients with sinus rhythm (n = 18) or atrial fibrillation (n = 12). VENC-CMR velocity measurements were performed perpendicular to the orifice of the LAA. Peak velocities were measured of passive diastolic LAA emptying (e-wave) in all patients. Peak velocities of active, late-diastolic LAA emptying (a-wave) were assessed in patients with sinus rhythm. Correlation and agreement was analyzed between VENC-CMR and TEE measurements of e- and a-wave peak velocities. A significant correlation and good agreement was found between VENC-CMR and TEE measurements of maximal e-wave velocities (r = 0.61, P < 0.001; mean difference 0 ± 10 cm/s). The a-wave was detectable by VENC-CMR in all patients with sinus rhythm. Correlation was also significant for measurements of peak a-wave velocities between VENC-CMR and TEE (r = 0.71, P < 0.001). There was no significant correlation of LAA emptying velocities with clinical characteristics and only a modest negative correlation of passive LAA emptying with LA function. The assessment of active and passive LAA emptying by VENC-CMR is feasible. Further evaluation is required of potential future clinical applications such as risk stratification for cardioembolic stroke.
    Journal of Cardiovascular Magnetic Resonance 06/2012; 14:39. · 3.72 Impact Factor

Following (23) See all

Followers (34) See all