Keiko Otani

Hiroshima University · Research Institute for Radiation Biology and Medicine (RIRBM)

Topics (4)

Publications (21) View all

  • Article: TMEM158 and FBLP1 as novel marker genes of cisplatin sensitivity in non-small cell lung cancer cells.
    [show abstract] [hide abstract]
    ABSTRACT: ABSTRACT Even after development of molecular targeting therapies, platinum-based chemotherapy is still a standard care for treatment of locally advanced non-small cell lung cancer (NSCLC). So far, critical molecular markers capable to predict the therapeutic response in NSCLC patients remain undetermined. We here attempted to identify novel biomarker genes for cisplatin (CDDP) for a tailored therapy. Initial screening to explorer association of IC(50) values of CDDP obtained by MTT assay and gene expression levels measured with oligonucleotide microarray and real-time RT-PCR provided 6 candidate genes, namely, NUBPL, C9orf30, ZNF12, TMEM158, GSK3B, and FBLP1 using 9 lung cancer cells consisting of 3 small and 6 NSCLC cells. These 6 genes together with 5 reported biomarkers, i.e., GSTP1, ERCC1, BRCA1, FRAP1, and RRM1, were subjected to a linear regression analysis using 12 NSCLC cell lines including 6 additional NSCLC cells: only FBLP1 and TMEM158 genes showed positive associations with statistical significances (P = .016 and .026, respectively). The biological significance of these genes was explored by in vitro experiments: Knockdown experiments in PC-9/CDDP cells revealed that the reduced expression of TMEM158 significantly decreased the chemo-resistance against CDDP (P <.0001), while 2 transformants of PC-6 cells stably over-expressing FBLP1 resulted in an enhanced resistance to CDDP (P = .004 and P = .001). Furthermore, a stepwise multiple regression analysis demonstrated the best prediction formula could be fixed when we used expression data of TMEM158 and FBLP1 (R(2) = 0.755, P = .0018). TMEM158 and FBLP1 may be powerful predictive biomarkers for CDDP therapy in NSCLC.
    Experimental Lung Research 11/2012; 38(9-10):463-74. · 1.22 Impact Factor
  • Source
    Article: Investigation on circular asymmetry of geographical distribution in cancer mortality of Hiroshima atomic bomb survivors based on risk maps: analysis of spatial survival data.
    [show abstract] [hide abstract]
    ABSTRACT: While there is a considerable number of studies on the relationship between the risk of disease or death and direct exposure from the atomic bomb in Hiroshima, the risk for indirect exposure caused by residual radioactivity has not yet been fully evaluated. One of the reasons is that risk assessments have utilized estimated radiation doses, but that it is difficult to estimate indirect exposure. To evaluate risks for other causes, including indirect radiation exposure, as well as direct exposure, a statistical method is described here that evaluates risk with respect to individual location at the time of atomic bomb exposure instead of radiation dose. In addition, it is also considered to split the risks into separate risks due to direct exposure and other causes using radiation dose. The proposed method is applied to a cohort study of Hiroshima atomic bomb survivors. The resultant contour map suggests that the region west to the hypocenter has a higher risk compared to other areas. This in turn suggests that there exists an impact on risk that cannot be explained by direct exposure.
    Biophysik 02/2012; 51(2):133-41. · 1.70 Impact Factor
  • Article: Effect of age on the fractional anisotropy (FA) value of peripheral nerves and clinical significance of the age-corrected FA value for evaluating polyneuropathies.
    [show abstract] [hide abstract]
    ABSTRACT: We investigated the correlation between age and the fractional anisotropy (FA) values of peripheral nerves in healthy adults and compared the age-corrected FA values of peripheral nerves in healthy subjects and patients with polyneuropathy. The institutional review board approved this study and informed consent was obtained from all participants before entry into the study. We optimized diffusion tensor imaging using a 3-T magnetic resonance scanner and an extremity coil for scanning tibial nerves. The effect of age and sex on the FA values of tibial nerves in healthy volunteers was investigated and the age-corrected FA values of tibial nerves in healthy volunteers and patients with polyneuropathy were compared. The maximum FA values of the tibial nerves remained constant until age 45 (approximately 0.516); they subsequently decreased by 0.004/year in healthy volunteers. After removing the effect of age with an age-adjusted equation, the median maximum FA values in the volunteers and patients were 0.518 (range, 0.406-0.616) and 0.442 (range, 0.376-0.530), respectively. The age-corrected FA values were significantly lower in the patients than the healthy volunteers (p < 0.001). There was no significant gender-related difference in the maximum FA values of the tibial nerves (p = 0.416). The age-corrected FA value of the peripheral nerves helps to differentiate between age-related peripheral nerve degeneration and polyneuropathies.
    Neuroradiology 11/2011; 54(8):815-21. · 2.82 Impact Factor
  • Article: Evaluation of lumber nerve root compression using thin-slice thickness coronal magnetic resonance imaging: three-dimensional fat-suppressed multi-shot balanced non-steady-state free precession versus three-dimensional T1-weighted spoiled gradient-recalled echo.
    [show abstract] [hide abstract]
    ABSTRACT: The aim of this study was to compare the three-dimensional fat-suppressed balanced non-steady-state free precession (3D FS-nSSFP) sequence and the 3D T1-weighted spoiled gradient-recalled echo (3D T1-GRE) sequence for evaluating lumbar nerve root compression with continuous thin-slice coronal magnetic resonance (MR) images. The institutional review board approved this study, and written informed consent was obtained from all 35 patients. We optimized continuous 2.5-mm thick lumbar coronal images with 3D FS-nSSFP and 3D T1-GRE. We calculated the contrast-to-noise ratio (CNR) for nerve roots and other structures on images with the two sequences. With knowledge of the final diagnosis, we assessed the visibility of nerve root compression on these images. The CNR values of nerve roots were significantly higher on images with 3D FS-nSSFP than on those with 3D T1-GRE. These continuous thin-slice coronal images facilitated visualization of nerve root compression in >91% of patients. There was no statistically significant difference between the two sequences in the detection of nerve root compression. Continuous thin-slice coronal MR images using 3D FS-nSSFP and 3D T1-GRE sequences are sufficient to evaluate lumbar nerve root compression, and 3D FS-nSSFP is superior to 3D T1-GRE for depiction of lumbar nerve roots.
    Japanese journal of radiology 11/2011; 29(9):623-9. · 0.65 Impact Factor
  • Article: Optimal fast T2-weighted magnetic resonance microscopy imaging of the eye and its clinical application.
    [show abstract] [hide abstract]
    ABSTRACT: To compare a half-Fourier single-shot rapid acquisition with relaxation enhancement (RARE) sequence with a balanced steady-state free precession (b-SSFP) sequence in the evaluation of the eye using magnetic resonance (MR) microscopy imaging and to clarify the usefulness of RARE microscopy imaging in evaluating nonoperative glaucoma patients and patients who have undergone surgery for glaucoma or cataract. One-mm and 2-mm slice thickness images of RARE sequence and b-SSFP sequence using a 1.5 T MR unit and a 23-mm microscopy coil were obtained in eight healthy volunteers. The signal-to-noise (S/N) ratio of aqueous humor in the anterior chamber was measured quantitatively and visualization of the anterior chamber anatomy was assessed qualitatively. Furthermore, we evaluated 21 glaucoma patients (including six postoperative patients) and four patients after cataract surgery with 2-mm slice thickness RARE MRI. The 2-mm slice thickness RARE imaging had a significantly greater S/N ratio than the 1-mm slice thickness RARE imaging (P < 0.05) and acquired the best image quality among the four types of images (P < 0.01). Additionally, 2-mm slice thickness RARE microscopy imaging could depict anterior chamber anatomy of glaucoma eyes and eyes after cataract surgery. We believe that optimal fast T2-weighted MR microimaging might become a useful ophthalmologic examination technique.
    Journal of Magnetic Resonance Imaging 05/2010; 31(5):1210-4. · 2.70 Impact Factor

Following (14) See all

Followers (15) See all