    Fully automated intrinsic respiratory and cardiac gating for small animal CT.

    J Kuntz, J Dinkel, S Zwick, T Bäuerle, M Grasruck, F Kiessling, R Gupta, W Semmler, S H Bartling

    Physics in medicine and biology. 04/2010; 55(7):2069-85.

    A fully automated, intrinsic gating algorithm for small animal cone-beam CT is described and evaluated. A parameter representing the organ motion, derived from the raw projection images, is used for both cardiac and respiratory gating. The proposed algorithm makes it possible to reconstruct motion-c... [more] A fully automated, intrinsic gating algorithm for small animal cone-beam CT is described and evaluated. A parameter representing the organ motion, derived from the raw projection images, is used for both cardiac and respiratory gating. The proposed algorithm makes it possible to reconstruct motion-corrected still images as well as to generate four-dimensional (4D) datasets representing the cardiac and pulmonary anatomy of free-breathing animals without the use of electrocardiogram (ECG) or respiratory sensors. Variation analysis of projections from several rotations is used to place a region of interest (ROI) on the diaphragm. The ROI is cranially extended to include the heart. The centre of mass (COM) variation within this ROI, the filtered frequency response and the local maxima are used to derive a binary motion-gating parameter for phase-sensitive gated reconstruction. This algorithm was implemented on a flat-panel-based cone-beam CT scanner and evaluated using a moving phantom and animal scans (seven rats and eight mice). Volumes were determined using a semiautomatic segmentation. In all cases robust gating signals could be obtained. The maximum volume error in phantom studies was less than 6%. By utilizing extrinsic gating via externally placed cardiac and respiratory sensors, the functional parameters (e.g. cardiac ejection fraction) and image quality were equivalent to this current gold standard. This algorithm obviates the necessity of both gating hardware and user interaction. The simplicity of the proposed algorithm enables adoption in a wide range of small animal cone-beam CT scanners.
  • 3.76
    Impact points
    Gating in small-animal cardio-thoracic CT.

    Soenke H Bartling, Jan Kuntz, Wolfhard Semmler

    Methods (San Diego, Calif.). 08/2009;

    Gating is necessary in cardio-thoracic small-animal imaging because of the physiological motions that are present during scanning. In small-animal computed tomography (CT), gating is mainly performed on a projection base because full scans take much longer than the motion cycle. This paper presents ... [more] Gating is necessary in cardio-thoracic small-animal imaging because of the physiological motions that are present during scanning. In small-animal computed tomography (CT), gating is mainly performed on a projection base because full scans take much longer than the motion cycle. This paper presents and discusses various gating concepts of small-animal CT, and provides examples of concrete implementation. Since a wide variety of small-animal CT scanner systems exist, scanner systems are discussed with respect to the most suitable gating methods. Furthermore, an overview is given of cardio-thoracic imaging and gating applications. The necessary contrast media are discussed as well as gating limitations. Gating in small-animal imaging requires the acquisition of a gating signal during scanning. This can be done extrinsically (additional hardware, e.g. electrocardiogram) or intrinsically from the projection data itself. The gating signal is used retrospectively during CT reconstruction, or prospectively to trigger parts of the scan. Gating can be performed with respect to the phase or the amplitude of the gating signal, providing different advantages and challenges. Gating methods should be optimized with respect to the diagnostic question, scanner system, animal model, type of narcosis and actual setup. The software-based intrinsic gating approaches increasingly employed give the researcher independence from difficult and expensive hardware changes.
  • 1.78
    Impact points
    Intrinsic gating for small-animal computed tomography: a robust ECG-less paradigm for deriving cardiac phase information and functional imaging.

    Julien Dinkel, Soenke H Bartling, Jan Kuntz, Michael Grasruck, Annette Kopp-Schneider, Masayoshi Iwasaki, Stefanie Dimmeler, Rajiv Gupta, Wolfhard Semmler, Hans-Ulrich Kauczor, Fabian Kiessling

    Circulation. Cardiovascular imaging. 11/2008; 1(3):235-43.

    BACKGROUND: A projection-based method of intrinsic cardiac gating in small-animal computed tomography imaging is presented. METHODS AND RESULTS: In this method, which operates without external ECG monitoring, the gating reference signal is derived from the raw data of the computed tomography project... [more] BACKGROUND: A projection-based method of intrinsic cardiac gating in small-animal computed tomography imaging is presented. METHODS AND RESULTS: In this method, which operates without external ECG monitoring, the gating reference signal is derived from the raw data of the computed tomography projections. After filtering, the derived gating reference signal is used to rearrange the projection images retrospectively into data sets representing different time points in the cardiac cycle during expiration. These time-stamped projection images are then used for tomographic reconstruction of different phases of the cardiac cycle. Intrinsic gating was evaluated in mice and rats and compared with extrinsic retrospective gating. An excellent agreement was achieved between ECG-derived gating signal and self-gating signal (coverage probability for a difference between the 2 measurements to be less than 5 ms was 89.2% in mice and 85.9% in rats). Functional parameters (ventricular volumes and ejection fraction) obtained from the intrinsic and the extrinsic data sets were not significantly different. The ease of use and reliability of intrinsic gating were demonstrated via a chemical stress test on 2 mice, in which the system performed flawlessly despite an increased heart rate. Because of intrinsic gating, the image quality was improved to the extent that even the coronary arteries of mice could be visualized in vivo despite a heart rate approaching 430 bpm. Feasibility of intrinsic gating for functional imaging and assessment of cardiac wall motion abnormalities was successfully tested in a mouse model of myocardial infarction. CONCLUSIONS: Our results demonstrate that self-gating using advanced software postprocessing of projection data promises to be a valuable tool for rodent computed tomography imaging and renders ECG gating with external electrodes superfluous.
  • Gating in small-animal cardio-thoracic CT

    Soenke H. Bartling, Jan Kuntz, Wolfhard Semmler

    Methods.

    Gating is necessary in cardio-thoracic small-animal imaging because of the physiological motions that are present during scanning. In small-animal computed tomography (CT), gating is mainly performed on a projection base because full scans take much longer than the motion cycle. This paper presents ... [more] Gating is necessary in cardio-thoracic small-animal imaging because of the physiological motions that are present during scanning. In small-animal computed tomography (CT), gating is mainly performed on a projection base because full scans take much longer than the motion cycle. This paper presents and discusses various gating concepts of small-animal CT, and provides examples of concrete implementation. Since a wide variety of small-animal CT scanner systems exist, scanner systems are discussed with respect to the most suitable gating methods. Furthermore, an overview is given of cardio-thoracic imaging and gating applications. The necessary contrast media are discussed as well as gating limitations. Gating in small-animal imaging requires the acquisition of a gating signal during scanning. This can be done extrinsically (additional hardware, e.g. electrocardiogram) or intrinsically from the projection data itself. The gating signal is used retrospectively during CT reconstruction, or prospectively to trigger parts of the scan. Gating can be performed with respect to the phase or the amplitude of the gating signal, providing different advantages and challenges. Gating methods should be optimized with respect to the diagnostic question, scanner system, animal model, type of narcosis and actual setup. The software-based intrinsic gating approaches increasingly employed give the researcher independence from difficult and expensive hardware changes.