Publications (125) View all
-
Article: Vertebral Augmentation with Nitinol Endoprosthesis: Clinical Experience in 40 Patients with 1-Year Follow-up.
Giovanni Carlo Anselmetti, Antonio Manca, Stefano Marcia, Gabriele Chiara, Stefano Marini, Gamal Baroud, Daniele Regge, Filippo Montemurro[show abstract] [hide abstract]
ABSTRACT: PURPOSE: This study was designed to assess the clinical outcomes of patients treated by vertebral augmentation with nitinol endoprosthesis (VNE) to treat painful vertebral compression fractures. METHODS: Forty patients with one or more painful osteoporotic VCF, confirmed by MRI and accompanied by back-pain unresponsive to a minimum 2 months of conservative medical treatment, underwent VNE at 42 levels. Preoperative and postoperative pain measured with Visual Analog Scale (VAS), disability measured by Oswestry Disability Index (ODI), and vertebral height restoration (measured with 2-dimensional reconstruction CT) were compared at last follow-up (average follow-up 15 months). Cement extravasation, subsequent fractures, and implant migration were recorded. RESULTS: Long-term follow-up was obtained in 38 of 40 patients. Both VAS and ODI significantly improved from a median of 8.0 (range 5-10) and 66 % (range 44-88 %) to 0.5 (range 0-8) and 6 % (range 6-66 %), respectively, at 1 year (p < 0.0001). Vertebral height measurements comparing time points increased in a statistically significant manner (ANOVA, p < 0.001). Overall cement extravasation rate was 9.5 %. Discal and venous leakage rates were 7.1 and 0 % respectively. No symptomatic extravasations occurred. Five of 38 (13.1 %) patients experienced new spontaneous, osteoporotic fractures. No device change or migration was observed. CONCLUSIONS: VNE is a safe and effective procedure that is able to provide long-lasting pain relief and durable vertebral height gain with a low rate of new fractures and cement leakages.CardioVascular and Interventional Radiology 05/2013; · 2.09 Impact Factor -
Article: Adverse events of computed tomography colonography: An Italian National Survey.
Franco Iafrate, Gabriella Iussich, Loredana Correale, Cesare Hassan, Daniele Regge, Emanuele Neri, Paolo Baldassari, Maria Ciolina, Alessandro Pichi, Marcella Iannitti, Davide Diacinti, Andrea Laghi[show abstract] [hide abstract]
ABSTRACT: AIM: To retrospectively study the frequency and magnitude of complications associated with computed tomography (CT) colonography in clinical practice. METHODS: A questionnaire on complications of CT colonography was sent to Italian public radiology departments identified as practicing CT colonography with a reasonable level of training. The frequency of complications and possible risk factors were retrospectively determined. Responses were collated and row frequencies determined. A multivariate analysis of the factors causing adverse events was also performed. RESULTS: 40,121 examinations were performed in13 centers during the study period. No deaths were reported. Bowel perforations occurred in 0.02% (7 exams). All perforations were asymptomatic and occurred in patients undergoing manual insufflation. Five perforations (71%) occurred in procedures performed following a recent colonoscopy. There was no significant difference between perforations associated with rectal balloon (0.017%) and those that were not (0.02%). Complications related to vasovagal reaction (either with or without spasmolytic) occurred in 0.16% (63 exams). All vasovagal reactions resolved in less than 3h, without any sequelae. CONCLUSIONS: Perforation rate at CT colonography in Italy is comparable with elsewhere in the world, occurring regardless of the experience of radiology centers. Although the risk is very small, it may not be negligible when compared with the risk of diagnostic colonoscopy.Digestive and Liver Disease 05/2013; · 3.05 Impact Factor -
Article: CT Colonography: Preliminary Assessment of a Double-Read Paradigm That Uses Computer-aided Detection as the First Reader.
Gabriella Iussich, Loredana Correale, Carlo Senore, Nereo Segnan, Andrea Laghi, Franco Iafrate, Delia Campanella, Emanuele Neri, Francesca Cerri, Cesare Hassan, Daniele Regge[show abstract] [hide abstract]
ABSTRACT: Purpose:To compare diagnostic performance and time efficiency of double-reading first-reader computer-aided detection (CAD) (DR FR CAD) followed by radiologist interpretation with that of an unassisted read using segmentally unblinded colonoscopy as reference standard.Materials and Methods:The local ethical committee approved this study. Written consent to use examinations was obtained from patients. Three experienced radiologists searched for polyps 6 mm or larger in 155 computed tomographic (CT) colonographic studies (57 containing 10 masses and 79 polyps ≥6 mm). Reading was randomized to either unassisted read or DR FR CAD. Data sets were reread 6 weeks later by using the opposite paradigm. DR FR CAD consists of evaluation of CAD prompts, followed by fast two-dimensional review for mass detection. CAD sensitivity was calculated. Readers' diagnoses and reviewing times with and without CAD were compared by using McNemar and Student t tests, respectively. Association between missed polyps and lesion characteristics was explored with multiple regression analysis.Results:With mean rate of 19 (standard deviation, 14; median, 15; range, 4-127) false-positive results per patient, CAD sensitivity was 90% for lesions 6 mm or larger. Readers' sensitivity and specificity for lesions 6 mm or larger were 74% (95% confidence interval [CI]: 65%, 84%) and 93% (95% CI: 89%, 97%), respectively, for the unassisted read and 77% (95% CI: 67%, 85%) and 90% (95% CI: 85%, 95%), respectively, for DR FR CAD (P = .343 and P = .189, respectively). Overall unassisted and DR FR CAD reviewing times were similar (243 vs 239 seconds; P = .623); DR FR CAD was faster when the number of CAD marks per patient was 20 or fewer (187 vs 220 seconds, P <01). Odds ratio of missing a polyp with CAD decreased as polyp size increased (0.6) and for polyps visible on both prone and supine scans (0.12); it increased for flat lesions (9.1).Conclusion:DR FR CAD paradigm had similar performance compared with unassisted interpretation but better time efficiency when 20 or fewer CAD prompts per patient were generated.© RSNA, 2013Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13121192/-/DC1.Radiology 04/2013; · 5.73 Impact Factor -
Chapter: Registration, Lesion Detection, and Discrimination for Breast Dynamic Contrast-Enhanced Magnetic Resonance Imaging
Valentina Giannini, Anna Vignati, Massimo De Luca, Silvano Agliozzo, Alberto Bert, Lia Morra, Diego Persano, Filippo Molinari, Daniele Regge03/2013: pages 572; -
Article: A Fully Automatic Multiscale 3-Dimensional Hessian-Based Algorithm for Vessel Detection in Breast DCE-MRI.
Anna Vignati, Valentina Giannini, Alberto Bert, Pasquale Borrelli, Massimo De Luca, Laura Martincich, Francesco Sardanelli, Daniele Regge[show abstract] [hide abstract]
ABSTRACT: OBJECTIVES: The objectives of this study were to develop a fully automatic method for detecting blood vessels in dynamic contrast-enhanced magnetic resonance imaging of the breast on the basis of a multiscale 3-dimensional Hessian-based algorithm and to evaluate the improvement in reducing the number of vessel voxels incorrectly classified as parenchymal lesions by a computer-aided diagnosis (CAD) system. MATERIALS AND METHODS: The algorithm has been conceived to work on images obtained with different sequences, different acquisition parameters, such as the use of fat-saturation, and different contrast agents. The analysis was performed on 28 dynamic contrast-enhanced magnetic resonance imaging examinations, with 39 malignant (28 principal and 11 satellite) and 8 benign lesions, acquired at 2 centers using 2 different 1.5-T magnetic resonance scanners, radiofrequency coils, and contrast agents (14 studies from group A and 14 studies from group B). The method consists of 2 main steps: (a) the detection of linear structures on 3-dimensional images, with a multiscale analysis based on the second-order image derivatives and (b) the exclusion of non-vessel enhancements based on their morphological properties through the evaluation of the covariance matrix eigenvalues. To evaluate the algorithm performances, the identified vessels were converted into a 2-dimensional vasculature skeleton and then compared with manual tracking performed by an expert radiologist. When assessing the outcome of the algorithm performances in identifying vascular structures, the following terms must be considered: the correct-detection rate refers to pixels identified by both the algorithm and the radiologist, the missed-detection rate refers to pixels detected only by the radiologist, and the incorrect-detection rate refers to pixels detected only by the algorithm. The Wilcoxon rank sum test was used to assess differences between the performances of the 2 subgroups of images obtained from the different scanners. RESULTS: For the testing set, which is composed of 28 patients from 2 different clinical centers, the median correct-detection rate was 89.1%, the median missed-detection rate was 10.9%, and the median incorrect-detection rate was 27.1%. The difference between group A and group B was not significant (P > 0.25). The exclusion of vascular voxels from the lesion detection map of a CAD system leads to a reduction of 68.4% (30.0%) (mean [SD]) of the total number of false-positives because of vessels, without a significant difference between the 2 subgroups (P = 0.50). CONCLUSIONS: The system showed promising results in detecting most vessels identified by an expert radiologist on both fat-saturated and non-fat-saturated images obtained from different scanners with variable temporal and spatial resolutions and types of contrast agent. Moreover, the algorithm may reduce the labeling of vascular voxels as parenchymal lesions by a CAD system for breast magnetic resonance imaging, improving the CAD specificity and, consequently, further stimulating the use of CAD systems in clinical workflow.Investigative radiology 12/2012; 47(12). · 4.85 Impact Factor